2-2 CP-5000 User’s Guide
Front Cover
Removal
The front cover must be removed to connect the Full Power Reserve
Battery and connect the external signal line for the CP-5000. To do so,
perform the following steps:
1. Disconnect the power cord from the power source if applicable.
2. Remove the top cover.
3. Lay the unit face up on a flat surface.
4. Facing the front of the unit, remove the two Phillips head screws in
the upper corners of the housing.
5. Press both of your hands flat against the sides of the front cover.
6. Pivot the front cover towards you. Support the front cover so that it
doesn’t stress the ground wire connections. Set face up on a flat
surface.
Installation
1. With the front cover on a flat surface and facing up, press both of
your hands flat against the sides.
2. Facing the bottom of the unit, set and align the tabs on the bottom of
the front cover with the grooves on the housing.
3. Pivot the front cover towards the housing. Reconnect the ground
wire, push the cover down in place and secure it with the two Phillips
head screws.
4. Reinstall the top cover. Reconnect the power cord to the power
source.